S-60 series 60W general switching power supply

 Model number and parameters

Model number

S-60-5

S-60-12

S-60-15

S-60-24

Related product

Order

Visiting...

Order

Order

DC output voltage

5V

12V

15V

24V

Output voltage error (Note: 2)

±2%

±1%

±1%

±1%

Rated output current

12A

5A

4A

2.5A

Output current rage

0-12A

0-5A

0-4A

0-2.5A

Wave and noise (Note: 3)

100mVp-p

75mVp-p

75mVp-p

75mVp-p

Inlets tability (Note: 4)

±0.5%

±0.5%

±0.5%

±0.5%

Load stability (Note: 5)

±1%

±0.5%

±0.5%

±0.5%

DC output power

60W

60W

60W

60W

Effciency

73%

78%

78%

82%

Adjustable range for DC voltage

+10,-5%

+10%

+10%

+10%

 General

Model number

S-60 series

AC input voltage range

85-132VAC/170-264VAC, selected by switch, 47-63Hz; 240-370VDC

Input current

2A/115V, 1A/230V

AC inrush current

Cold-start current: 30A/115V, 60A/230V

Leakage current

3.5mA/240VAC max

Overload proctection

105%-150% Type:Foldback current limiting Rest:auto-recovery

Temperature coefficient

±0.03%/°C (0-50°C)

Setup rise hold up time

800ms,50ms,10ms/150v,300ms,50ms,80ms/230v

Vibration

10-500HZ,2G 10min/1cycle, Periodfor 60min, Each axes

Dielectric strength

1.5KVac, 50/60 Hz for 1 min between input and output
1.5KVac, 50/60 Hz for 1 min between input and enclosure
0.5KVac, 50/60 Hz for 1 min between output and enclosure

Isolation resistance

100MΩ min. at 500 VDC

Working temperature humidity

-10°C-60°C (Refer to output characteristic figure), 20%-90%RH

Store temperature humidity

-20°C-85°C, 10%-95%RH

External dimension

157x97x38 mm

Weight

0.55kg

Safety standards

UL1012 TUV refer to 6050 (IEC,UL1950) verification

EMC standards

CISPR22(refer to 55022), IEC801-2,3,4IEC555-2 verification

Note

1. The testing condition for the above paramenter is: 230VAC input, rated load, 25°C, Humidity 70%RH.
2. Error, include the setting error, line stability and load stability. (Note:5)
3. Wave test: adopting A12 double wire for 20MHZ,and 0.1uF-47uF capacitor short-circuit for interrupting.
4. Inlet voltage stability test: when is over load,the lowest voltage of enter is representative to the highest voltage
5. Load stability test: The load is from 0% to 100%.