Menu
Your Cart

Hantek DSO5102B Digital Oscillsocope 2 Channels 100Mhz 1GSa/s UK Plug

Hantek DSO5102B Digital Oscillsocope 2 Channels 100Mhz 1GSa/s UK Plug
2-3 weeks
Hantek DSO5102B Digital Oscillsocope 2 Channels 100Mhz 1GSa/s UK Plug
190.000 OMR
  • Stock: 2-3 weeks
  • Model: IC043

ltem Pictures.jpg_01.jpg_02.jpg_04.jpg_03.jpg_05.jpgltem Description.jpg

 


• 200/100/60MHz bandwidths
•1GSa/s Real Time sample rate
• Large (7.0-inch) color display,WVGA(800x480)

• Record length up to 1M
• Trigger mode: edge/pulse width/line selectable video/slop/overtime etc.
• USB host and device connectivity, standard
• Multiple automatic measurements
• Four math functions, including FFTs standard
• Provides software for PC real-time analysis

Specifications:

 

Model
DSO5202B
DSO5102B
DSO5062B
Bandwidth
200MHz
100MHz
60MHz
Real-time Sample Rate
1GSa/s
Equivalent Sample Rate
25GSa/s
Record Length(Sample Points)
Single-channel: Maximum 1M; Dual-channel:Maximum 512K (4K,16K,40K optional)
SEC/DIV Range
4nS/div-40S/div (in a 2, 4, 8 sequence)
Delay Time Accuracy
500ps
Vertical
A/D Converter
8-bit resolution, each channel sampled simultaneously
VOLTS/DIV Range
2mV/div~5V/div at input BNC
Position Range
±50V(5V/div),±40V(2V/div~500mV/div),2V(200mV/div~50mV/div)±400mV(20mV/div~2mV/div)
Bandwidth Limit
20MHz
Rise Time at BNC
≤1.7ns
≤3.5ns
≤5.8ns
DC Gain Accuracy
±4% for Sample or Average acquisition mode, 5mV/div to 2mV/div
±3% for Sample or Average acquisition mode, 5V/div to 10mV/div
Trigger
Trigger Sensitivity
(Edge Trigger Type)
DC: CH1/CH2(Typical) 1div from DC to 10MHz;1.5div from 10MHz to Full
EXT(Typical) 200mV from DC to 40MHz
EXT/5(Typical) 1V from DC to 40MHz
AC: Attenuates signals below 10Hz

HF Reject: Attenuates signals above 80kHz

LF Reject: Attenuates signals below 150kHz

Noise Reject: Reduces trigger sensitivity
Trigger Level Range
CH1,CH2: ±8 divisions from center of screen
EXT: ±1.2V EXT/5: ±6V
Trigger Level Accuracy,
typical (Accuracy is for signals having rise and fall times ≥20ns)
CH1,CH2: ±(0.3div×V/div) (within ±4 divisions from center of screen)
EXT: ±(6% of setting + 40mV)
EXT/5: ±(6% of setting + 200mV)
Holdoff Range
100ns-10s
Trigger Type
Edge
Trigger on the rising or falling edge
Pulse Width
Trigger (when >,<,=,≠) on positive or negative pulses
Pulse Width Range: 20ns-10s
Video
Trigger on an NTSC, PAL, or SECAM standard video signal
Line Range: 1-525 (NTSC), 1-625 (PAL/SECAM)
Slope
Trigger (when >,<,=,≠) on a positive or negative slope
Set Time: 20ns–10s
Overtime
from the rising or falling edge
Set Time: 20-10s
Alternate
Internal trigger on edge, pulse width, video or slope
Measurement
Cursors
Manual: The difference between voltage cursors V; the difference between time cursors T; 1/T calculated by Hz.
Tracing: The voltage and time at a waveform point
Automatic
Pk-Pk, Max, Min, Mean, Cyc RMS, Frequency, Period, Rise Time, Fall Time, Positive Width, Negative Width